Foto | Mfr. Teil # | Lagerbestand | Preis | Menge | Datenblatt | Packaging | Series | ProductStatus | Type | DisconnectType | NumberofPositions | NumberofLevels | Terminal-Width | TerminationStyle | Current-IEC | Voltage-IEC | Current-UL | Voltage-UL | WireGaugeorRange-AWG | WireGaugeorRange-mm² | Features | Color |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
912016CONN TERM BLK FEED THRU 12-26AWG |
2949 | 15.18 |
In den WarenkorbJetzt anfragen |
Bulk | W | Active | Feed Through | - | 3 | 2; Connected | 5.0mm | Screw | - | - | - | - | 12-26 AWG | 2.5mm² | LED | - | ||
912023CONN TERM BLK FEED THRU 12-26AWG |
2870 | 15.18 |
In den WarenkorbJetzt anfragen |
Bulk | W | Active | Feed Through | - | 3 | 2; Connected | 5.0mm | Screw | - | - | - | - | 12-26 AWG | 2.5mm² | LED | - | ||
2002-3221/1000-434COMPONENT TERMINAL BLOCK; TRIPLE |
3505 | 15.78 |
In den WarenkorbJetzt anfragen |
Datenblatt |
Box | TOPJOB®S | Active | Feed Through | - | 6 | 3 | 5.2mm | Push In, Spring | 25 mA | - | 20 A | 600V | 12-22 AWG | 0.25-4mm² | LED, Resistor | Gray | |
2002-3221/1000-413COMPONENT TERMINAL BLOCK; TRIPLE |
2912 | 15.78 |
In den WarenkorbJetzt anfragen |
Datenblatt |
Box | TOPJOB®S | Active | Feed Through | - | 6 | 3 | 5.2mm | Push In, Spring | 25 mA | - | 20 A | 600V | 12-22 AWG | 0.25-4mm² | LED, Resistor | Gray | |
1879750000CONN TERM BLK DISCONN 12-26AWG |
2048 | 15.20 |
In den WarenkorbJetzt anfragen |
Datenblatt |
Bulk | Z | Active | Disconnect | Fuse, Screw Cap | 2 | 1 | 12.2mm | Push In, Spring | 10 A | - | 10 A | 600V | 12-26 AWG | 0.5-10mm² | LED | - | |
1867500000ZSI 6-2 2X2.5/G20/LD1 |
3504 | 15.20 |
In den WarenkorbJetzt anfragen |
Bulk | * | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | ||
727-2254-LEVEL SAME POTENTIAL TERMINAL |
3376 | 15.80 |
In den WarenkorbJetzt anfragen |
Datenblatt |
Box | - | Active | Feed Through | - | 16 | 4 | 7.6mm | Push In, Spring | 18 A | 250V | - | - | 16-28 AWG | 0.08-1.5mm² | - | Orange | |
280-5714-CONDUCTOR SENSOR TERMINAL BLOC |
2369 | 15.80 |
In den WarenkorbJetzt anfragen |
Datenblatt |
Box | - | Active | Disconnect, Isolated (3) | Component Plug | 5 | 4; 1 Grounded | 5.0mm | Push In, Spring | 6 A | 250V | - | - | 12-28 AWG | 0.08-2.5mm² | - | Gray | |
727-2354-LEVEL SAME POTENTIAL TERMINAL |
3716 | 15.80 |
In den WarenkorbJetzt anfragen |
Datenblatt |
Box | - | Active | Feed Through | - | 16 | 4 | 7.6mm | Push In, Spring | 18 A | 250V | - | - | 16-28 AWG | 0.08-1.5mm² | - | Orange | |
727-2274-LEVEL SAME POTENTIAL TERMINAL |
3475 | 15.80 |
In den WarenkorbJetzt anfragen |
Datenblatt |
Box | - | Active | Feed Through | - | 16 | 4 | 7.6mm | Push In, Spring | 18 A | 250V | - | - | 16-28 AWG | 0.08-1.5mm² | - | Gray | |
727-2374-LEVEL SAME POTENTIAL TERMINAL |
2225 | 15.80 |
In den WarenkorbJetzt anfragen |
Datenblatt |
Box | - | Active | Feed Through | - | 16 | 4 | 7.6mm | Push In, Spring | 18 A | 250V | - | - | 16-28 AWG | 0.08-1.5mm² | - | Gray | |
400-465/465-1112-CONDUCTOR GROUND TERMINAL BLOC |
2702 | 15.81 |
In den WarenkorbJetzt anfragen |
Datenblatt |
Box | - | Active | Ground, Earth | - | 2 | 1 | 16.0mm | Screw | - | - | - | - | 2-6 AWG | 16-35mm² | - | Green, Yellow | |
870-541/281-872COMPONENT TERMINAL BLOCK; DOUBLE |
2836 | 15.81 |
In den WarenkorbJetzt anfragen |
Datenblatt |
Box | - | Active | Feed Through | - | 4 | 2 | 5.0mm | Push In, Spring | 500 mA | - | - | - | 12-28 AWG | 0.08-2.5mm² | Diode | Gray | |
2467.2FUSE DISCONNECT TERMINAL |
2072 | 15.83 |
In den WarenkorbJetzt anfragen |
Datenblatt |
Box | STK | Active | Disconnect | Fuse, Lever | 2 | 1 | 8.0mm | Screw | 6.3 A | 115V | - | - | 12-22 AWG | 0.2-4mm² | LED | Beige | |
2468.2FUSE DISCONNECT TERMINAL |
3854 | 15.83 |
In den WarenkorbJetzt anfragen |
Datenblatt |
Box | STK | Active | Disconnect | Fuse, Lever | 2 | 1 | 8.0mm | Screw | 6.3 A | 230V | - | - | 12-22 AWG | 0.2-4mm² | LED | Beige | |
3035726CONN TERM BLK GROUND 8-24 AWG |
3054 | 15.84 |
In den WarenkorbJetzt anfragen |
Datenblatt |
Bulk | CLIPLINE STMED | Active | Ground, Earth | - | 2 | 1 | 8.2mm | Push In, Spring | - | - | - | - | 8-24 AWG | 0.2-10mm² | - | Green, Yellow | |
2000-5317/101-0003-CONDUCTOR ACTUATOR SUPPLY TERM |
3708 | 15.87 |
In den WarenkorbJetzt anfragen |
Datenblatt |
Box | TOPJOB®S | Active | Feed Through | - | 8 | 3 | 7.0mm | Push In, Spring | 13.5 A | 250V | 15 A | 300V | 16-24 AWG | 0.14-1.5mm² | - | Gray | |
2000-5317/102-0003-CONDUCTOR ACTUATOR SUPPLY TERM |
3377 | 15.87 |
In den WarenkorbJetzt anfragen |
Datenblatt |
Box | TOPJOB®S | Active | Feed Through | - | 8 | 3 | 7.0mm | Push In, Spring | 13.5 A | 250V | 15 A | 300V | 16-24 AWG | 0.14-1.5mm² | - | Gray | |
270-574/281-4834-CONDUCTOR SENSOR SUPPLY TERMIN |
3760 | 15.87 |
In den WarenkorbJetzt anfragen |
Datenblatt |
Box | - | Active | Feed Through, Isolated (3) | - | 5 | 4; 2 Connected | 5.0mm | Push In, Spring | - | - | - | - | 12-28 AWG | 0.08-2.5mm² | LED, Resistor | Orange | |
0354760000CONN TERM BLK GROUND 2-8AWG |
2671 | 15.28 |
In den WarenkorbJetzt anfragen |
Datenblatt |
Bulk | SAK | Active | Ground, Earth | - | 2 | 1 | 16.0mm | Screw | - | - | - | - | 2-8 AWG | 10-35mm² | - | Green, Yellow |
Tel